LX Air-cooled Packged Industrial Chiller
Industrial water chiller for attention
|
Model
|
LXL-25F
|
LXH-35F
|
LXH-50F
|
LXH-70F
|
LXH-90F
|
LXH-120F
|
|
|
Power Supply(V~PH~Hz)
|
220V~50Hz 380V~3PH~50Hz
|
380V~3PH~50Hz
|
|||||
|
Nominal Capacity(W)
|
2700
|
3750
|
5270
|
7200
|
11350
|
14940
|
|
|
Cooling Capacity(M3)
|
1
|
1.5
|
2
|
3
|
4
|
5
|
|
|
Input Power(W)
|
950
|
1300
|
1820
|
2400
|
3000
|
3800
|
|
|
Input Current(A)
|
4.2/1.7
|
6/2.4
|
8.8/3.1
|
11.5/4.2
|
5.5
|
7.4
|
|
|
Condenser
|
Fan Power(W)
|
35
|
35
|
35
|
90
|
140
|
200
|
|
Wind Model
|
Top/Side
|
Top/Side
|
Top/Side
|
Top/Side
|
Top
|
Top
|
|
|
Finned coil air cooled condenser
|
|||||||
|
Dia.of Connective Pipe(mm)
|
32
|
50
|
50
|
50
|
50
|
50
|
|
|
Outside Dimesion Device(mm)H×L×W
|
750×470×460
980×280×560
|
750×470×460
980×280×560
|
750×470×460
1050×300×620
|
970×760×660
900×600×850
|
970×760×660
|
970×760×660
1250×600×1000
|
|
|
Flew Control Device
|
Capillary tube/expansion valve
|
||||||
|
Evaporator
|
Copper coil evaporator
|
||||||
|
Refrigerant
|
R22
|
||||||
|
Safety Device
|
Motor overload\high and low voltage\water cut\low temperature
|
||||||
|
Grounding Requirement(Ω)
|
≤5
|
||||||
|
Insulation Resistance
|
1
|
||||||
Features:
1,This series of products adopt key parts such as high quality compressor and pumps imported from Europe ,America that makes it energy-saving and durable.
2, Using super-larger surface-area condensing coil and specially made bland blower higher heating radiation.
3, Easy installation;unnecessary to use the cooling tower.
4, Over-current relay,high and low pressure limit control,starting delay time,ready to alarm and display at any time.
1,This series of products adopt key parts such as high quality compressor and pumps imported from Europe ,America that makes it energy-saving and durable.
2, Using super-larger surface-area condensing coil and specially made bland blower higher heating radiation.
3, Easy installation;unnecessary to use the cooling tower.
4, Over-current relay,high and low pressure limit control,starting delay time,ready to alarm and display at any time.
Industrial water chiller for attention
1, unit run-time power supply voltage must be stable, considering all factors, blood pressure, the work crew to maintain the rated voltage of less than + -10%, voltage too high or too low are the adverse effects of the crew.
2, power frequency should be maintained at rated + -2%.
3, for the protection of human security, if the body leakage avoid the risk of electric shock, Shell should have a good crew, reliable ground fault protection device has been accidents, according to strict regulations require construction electrician.
4, transportation or move out room, do not impact with the ground, causing too much impact.
5, the room should have sufficient space for the installation and maintenance unit, taking into account the adequate space extubation.
6, the installation of the selected sites:
①, avoid direct sunlight installations or other heat source will be directly radiation areas.
②, from power nearly facilitate wiring.
③, solid ground strength, and the noise does not easily cause resonance of places.
④, placed in the house, choose a well-ventilated, humidity small, less suitable places.
②, from power nearly facilitate wiring.
③, solid ground strength, and the noise does not easily cause resonance of places.
④, placed in the house, choose a well-ventilated, humidity small, less suitable places.
7, to facilitate the discharge cooling water and chilled water, basic units must be installed around the gutter.
8, chilled water and cooling water undesirable not only led to the scaling of heat transfer, heat transfer efficiency from lower and the weakening performance unit will heat pipe corrosion caused major accidents, customers should be in strict accordance with the GB50050-1995 "Design of industrial circulating cooling water treatment norms "at the request of water treatment.
9, vertical flow switch should be installed in the outlet pipe into the pipes or the level of the paragraph.
10, flow switch to the direction of flow at least six times the pipeline diameter of straight pipe section; flow switch to the direction of flow at least four times the diameter of straight pipe pipeline paragraph; should not be installed in the near Bend, in the vicinity of the valve orifice and .
11, in order to prevent flow switch trembled, the water system should be all of the gas emissions out.
12, Australian customs regulation flowmeter, it is lower than the minimum flow of water in a state separate from the flow. When the water flow to meet the requirements, flow switch should remain closed state.
Specifications:low noise ,high reliability,low vibration,high efficiency
Export Markets:millde east; south america;africa
various compressors is used for air-conditioner as a replacement parts ,and they are high quality and excellent matching.
Specifications:low noise ,high reliability,low vibration,high efficiency
Export Markets:millde east; south america;africa
various compressors is used for air-conditioner as a replacement parts ,and they are high quality and excellent matching.
Category: Industrial Water Chiller
Related Category: Carrier 06E Series piston compressors Chillers and Units Piston Air conditioning Compressors commercial Vertical Compressor Marine Horizontal Compressor
.gif)

.jpg)
.jpg)
.jpg)

.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)


English
German
Spanish
French
Italian
Portuguese
Japanese
Korean
Arabic
Russian
Indonesian
Vietnamese
By 