You are here:  homeproductsIndustrial Water Chiller Unit SeriesIndustrial Chiller
Products List
  • Air-Conditioning Compressor Series
  • Stable Speed Series Compressors
  • H Type Compressors
  • D Series Compressors
  • Inverter Series Compressors
  • R410A Series Compressors
  • R134a Series Compressors
  • Air-Conditioning Scroll Compressors
  • Semi-hermetic Reciprocating Compressors
  • 06D Series Piston Compressors
  • 06E Series Piston Compressors
  • 06CC Series Piston Compressors
  • R134a Series Compressors
  • R404A/R507A Series Compressors
  • R407C Series Compressors
  • R22 Series Compressors
  • Horizontal Compressor Series
  • R22 Series Horizontal Rotary Compressors
  • R407C Series Horizontal Compressors
  • Vertical Compressor Series
  • R22 Series Vertical Compressors
  • R407C Series Vertical Compressors
  • R410A Series Vertical Compressors
  • Piston A/C Compressor Series
  • R12 Series Piston Compressors
  • R22 Series Piston Compressors
  • R22 & R407C Series Piston Compressors
  • Low Temperature Chiller Unit Series
  • LHJL Series Low Temperature Unit
  • LXJL Series Low Temperature Unit
  • Industrial Water Chiller Unit Series
  • Car Air Conditioning Compressors
  • Fixed Displacement Compressors
  • DY5H09
  • DY5H11
  • DY5H14
  • DY5H16
  • DYHT6
  • DY7B10
  • DY7H13
  • DY7H15
  • DY10P08
  • DY10PA15C
  • DY10PA17C
  • DY10S17C
  • DY10S20C
  • Variable Displacement Compressors
  • DYV5
  • DYCVC
  • DY6V12
  • DY7V16
  • DY7SBU16C
  • Refrigerating Units
  • Environment-Friendly Chillers
  • Industrial Chillers
  • Screw Type Chillers
  • Laser Chillers
  • Heat and Cold Chillers
  • Low Temperature Chillers
  • PCB Chillers
  • Cooling Towers
  • Air-Coolers
  • Heating Pump Series
  • Household Series
  • Villa Servies
  • Individuality Series
  • Import Series
  • Floor-heating Equipment
  • Swimming Pool Equipment
  • Heating and Ventilation series
  • Energy Saving Air Curtain Series
  • Classical Air Curtain Series
  • Exalted Air Curtain Series
  • Faddish Air Curtain Series
  • Cultured Air Curtain Series
  • Deluxe Air Curtain Series
  • Industrial Exhausting Fan Series
  • Air-conditioning Parts
  • Refrigerant Series
  • Capacitor Series
  • Metallic Polypropylene Film Capacitors
  • Aluminium Electrolytic Capacitors
  • Power Capacitors
  • Brass Fitting Series
  • Copper Fitting Series
  • Insulated Pipe Fitting Series
  • 4-way Reversing Valves
  • Solenoid Valves
  • Pressure Switches
  • Expansion Valves
  • Sighe Glasses
  • Filter Drieres
  • air conditioner plastic Fan Blades and metal fanblade Series
  • Axial Fans with External Rotor Motor
  • Fan Motors
  • YWF Series Axial Motors
  • YZF Series Axial Motors
  • YJF Series Axial Motors
  • Fan Blades
  • Cross Flow Fan Blades
  • Axial Flow Fan Blades
  • Centrifugal Flow Fan Blades
  • Home Electrical Parts series
  • Rubber Washing Machine Parts Series
  • Gear Box Series
  • Washing Machine Connection Pipes
  • Online Service
    Forrest:  
    Industrial Chiller
    View more specifications Industrial Chiller for you
    Model No: LX Water Cooled Box type
    Place of Origin: Zhejiang
    Function: air-conditioner
    Certificate: TUV CE ROHS
    Export Area: millde east; south america


    Add to Basket
     Description
    Payment & Shipping Terms
    Payment Term: T/T,L/C;D/P  
    MOQ: 50 pcs  
    Means of Transport: by sea ;by air ;by train  
    Supply Capacity
    Packing: with requirement
    Delivery Date: 30 days
    LX Water Cooled Box-type industrial Chiller
    Chiller Models
    LXL-80W
    LXL-120W
    LXL-240W
    LXL-250W
    LXL-340W
    LXL-410W
    LXL-500W
    LXL-680W
    LXL-830W
    Capacity
    W
    8080
    12730
    23750
    25170
    34000
    41500
    50350
    68000
    82840
    Input Power
    KW
    2.3
    3.8
    6
    7.5
    9
    11.3
    15
    18.3
    22.5
    Freezing Water Flow
    L/min
    34
    56
    88
    114
    148
    169
    220
    290
    337
    Inlet and Outside Pipe
    Mm
    φ40
    φ40
    φ50
    φ50
    φ50
    φ50
    φ65
    φ65
    φ85
    Pump Power
    KW
    0.5
    0.5
    1
    1
    2
    2
    3
    3
    3
    Tank Volume
    L
    45
    45
    120
    120
    180
    300
    300
    300
    350
    Outside Dimesion
    H×L×W
    mm
    850×580×950
    1400×650×1300
    188×1005×1300
    2335×1005×1515
    Refrigrant
    R22
    Power Supply
    380V~3PH~50Hz
    Flow Control Device
    Capillary tube/expansion valve
    Condenser
    Shell and tube condenser
    Evaporator
    Copper coil evaporator

    Features:
    1,This series of products adopt key parts such as high quality compressor and pumps imported from Europe ,America that makes it energy-saving and durable.
    2,Using mic-computer controlled digital thermostat with the temperature can be accurately within the scope of 3℃to25℃.
    3,Equipped with opened water tank,easier and quicker forcleaning and maintenance.
    4,Over-current relay,high and low pressure limit control,starting delay time,ready to alarm and display at any time.
    Industrial water chiller for attention
    1, unit run-time power supply voltage must be stable, considering all factors, blood pressure, the work crew to maintain the rated voltage of less than + -10%, voltage too high or too low are the adverse effects of the crew.
    2, power frequency should be maintained at rated + -2%.
    3, for the protection of human security, if the body leakage avoid the risk of electric shock, Shell should have a good crew, reliable ground fault protection device has been accidents, according to strict regulations require construction electrician.
    4, transportation or move out room, do not impact with the ground, causing too much impact.
    5, the room should have sufficient space for the installation and maintenance unit, taking into account the adequate space extubation.
    6, the installation of the selected sites:
    ①, avoid direct sunlight installations or other heat source will be directly radiation areas.
    ②, from power nearly facilitate wiring.
    ③, solid ground strength, and the noise does not easily cause resonance of places.
    ④, placed in the house, choose a well-ventilated, humidity small, less suitable places.
    7, to facilitate the discharge cooling water and chilled water, basic units must be installed around the gutter.
    8, chilled water and cooling water undesirable not only led to the scaling of heat transfer, heat transfer efficiency from lower and the weakening performance unit will heat pipe corrosion caused major accidents, customers should be in strict accordance with the GB50050-1995 "Design of industrial circulating cooling water treatment norms "at the request of water treatment.
    9, vertical flow switch should be installed in the outlet pipe into the pipes or the level of the paragraph.
    10, flow switch to the direction of flow at least six times the pipeline diameter of straight pipe section; flow switch to the direction of flow at least four times the diameter of straight pipe pipeline paragraph; should not be installed in the near Bend, in the vicinity of the valve orifice and .
    11, in order to prevent flow switch trembled, the water system should be all of the gas emissions out.
    12, Australian customs regulation flowmeter, it is lower than the minimum flow of water in a state separate from the flow. When the water flow to meet the requirements, flow switch should remain closed state.

    Specifications:low noise ,high reliability,low vibration,high efficiency
    Export Markets:millde east; south america;africa
    various compressors  is used for air-conditioner as a replacement parts ,and they are high quality and excellent matching.