You are here:  homeproductsIndustrial Water Chiller Unit SeriesOpened Water Cooling Chiller Unit
Products List
  • Air-Conditioning Compressor Series
  • Stable Speed Series Compressors
  • H Type Compressors
  • D Series Compressors
  • Inverter Series Compressors
  • R410A Series Compressors
  • R134a Series Compressors
  • Air-Conditioning Scroll Compressors
  • Semi-hermetic Reciprocating Compressors
  • 06D Series Piston Compressors
  • 06E Series Piston Compressors
  • 06CC Series Piston Compressors
  • R134a Series Compressors
  • R404A/R507A Series Compressors
  • R407C Series Compressors
  • R22 Series Compressors
  • Horizontal Compressor Series
  • R22 Series Horizontal Rotary Compressors
  • R407C Series Horizontal Compressors
  • Vertical Compressor Series
  • R22 Series Vertical Compressors
  • R407C Series Vertical Compressors
  • R410A Series Vertical Compressors
  • Piston A/C Compressor Series
  • R12 Series Piston Compressors
  • R22 Series Piston Compressors
  • R22 & R407C Series Piston Compressors
  • Low Temperature Chiller Unit Series
  • LHJL Series Low Temperature Unit
  • LXJL Series Low Temperature Unit
  • Industrial Water Chiller Unit Series
  • Car Air Conditioning Compressors
  • Fixed Displacement Compressors
  • DY5H09
  • DY5H11
  • DY5H14
  • DY5H16
  • DYHT6
  • DY7B10
  • DY7H13
  • DY7H15
  • DY10P08
  • DY10PA15C
  • DY10PA17C
  • DY10S17C
  • DY10S20C
  • Variable Displacement Compressors
  • DYV5
  • DYCVC
  • DY6V12
  • DY7V16
  • DY7SBU16C
  • Refrigerating Units
  • Environment-Friendly Chillers
  • Industrial Chillers
  • Screw Type Chillers
  • Laser Chillers
  • Heat and Cold Chillers
  • Low Temperature Chillers
  • PCB Chillers
  • Cooling Towers
  • Air-Coolers
  • Heating Pump Series
  • Household Series
  • Villa Servies
  • Individuality Series
  • Import Series
  • Floor-heating Equipment
  • Swimming Pool Equipment
  • Heating and Ventilation series
  • Energy Saving Air Curtain Series
  • Classical Air Curtain Series
  • Exalted Air Curtain Series
  • Faddish Air Curtain Series
  • Cultured Air Curtain Series
  • Deluxe Air Curtain Series
  • Industrial Exhausting Fan Series
  • Air-conditioning Parts
  • Refrigerant Series
  • Capacitor Series
  • Metallic Polypropylene Film Capacitors
  • Aluminium Electrolytic Capacitors
  • Power Capacitors
  • Brass Fitting Series
  • Copper Fitting Series
  • Insulated Pipe Fitting Series
  • 4-way Reversing Valves
  • Solenoid Valves
  • Pressure Switches
  • Expansion Valves
  • Sighe Glasses
  • Filter Drieres
  • air conditioner plastic Fan Blades and metal fanblade Series
  • Axial Fans with External Rotor Motor
  • Fan Motors
  • YWF Series Axial Motors
  • YZF Series Axial Motors
  • YJF Series Axial Motors
  • Fan Blades
  • Cross Flow Fan Blades
  • Axial Flow Fan Blades
  • Centrifugal Flow Fan Blades
  • Home Electrical Parts series
  • Rubber Washing Machine Parts Series
  • Gear Box Series
  • Washing Machine Connection Pipes
  • Online Service
    Forrest:  
    Opened Water Cooling Chiller Unit
    View more specifications Opened Water Cooling Chiller Unit for you
    Model No: LXS Series
    Place of Origin: Zhejiang
    Function: air-conditioner
    Certificate: TUV CE ROHS
    Export Area: millde east; south america


    Add to Basket
     Description
    Payment & Shipping Terms
    Payment Term: T/T,L/C;D/P  
    MOQ: 50 pcs  
    Means of Transport: by sea ;by air ;by train  
    Supply Capacity
    Packing: with requirement
    Delivery Date: 30 days
    LXS Series Opened Water Cooling Chiller Unit
    Model Capacity kw Compressor Evaporator Condenser Size Re.Weight kg
    Power kw Shape Water Charge m3/h Pipe Size G Shape Water Charge m3/h Pipe Size G Shape L mm W mm H mm
    LXS-1HP 3 0.75
    Complete Hermetical
    0.5 1/2〞
    Shell and tube
    1 1/2〞 Shell and tube 750 400 1000 140
    LXS-2HP 6 1.5 1 1/2〞 2 1/2〞 1000 400 1200 180
    LXS-3HP 9 2.25 1.5 1〞 3 1〞 1100 500 1400 240
    LXS-5HP 15 3.75 2.5 1-1/2〞 4 1-1/2〞 1300 500 1400 300
    LXS-8HP 20 5.5 3.5 1-1/2〞 5 1-1/2〞 1400 500 1400 350
    LXS-10HP 30 7.5 5 2〞 6.5 2〞 1560 500 1400 370
    LXS-12HP 40 9 7 2〞 8.5 2〞 1740 500 1400 520
    LXS-20HP 60 16 11 2〞 13 2〞 1920 600 1400 750
    LXS-25HP 70 21 12 2〞 15 2〞 2160 600 1400 810
    LXS-30HP 90 24 15 2-1/2〞 21 2-1/2〞 2330 600 1450 970
    LXS-40HP 120 32 22 2-1/2〞 26 2-1/2〞 2530 600 1450 1300
    LXS-50HP 140 42 24 2-1/2〞 30 2-1/2〞 2880 600 1450 1600
    LXS-60HP 180 48 33 3〞 39 3〞 3150 650 1550 2100
    LXS-75HP 210 63 36 3〞 45 3〞 3540 650 1550 2600
    LXS-80HP 240 64 44 3〞 52 3〞 2830 1500 1450 2950
    LXS-100HP 280 84 48 3〞 60 3〞 3150 1500 1450 3650
    LXS-120HP 360 96 66 4〞 78 4〞 3150 1500 1550 5350
    LXS-150HP 420 126 72 4〞 90 4〞 3540 1500 1550 6280

    Chiller feature
    1, this series of products using high-quality Division I compressors, pumps, and other core components of outsourcing, energy saving durable.
    3, the new shell and tube condenser, and heat exchanger performance strong.
    4, efficient intelligent control can be set to achieve functional, timing week, parameter browsing, security, fault alarm functions.
    5, Box isolation unit by design, multi-noise reduction processing, low noise, the use of more convenient.
    6, open with a stainless steel water tanks, washing maintaining convenient and quick.
    7, unit using modular design can start grading, reducing the power grid unit starting current of the impact of new unique wetlands screens evaporative cooling refrigeration systems to ensure that the units tall 50 ° C in the hot weather can still be normal refrigeration run.
    8, with current overload protection, high-latency and low-voltage protection, such as boot.
    9, to protect the installations, the police at any time that fault.
    10, the use of: plastic mold cooling industry, electroplating industry electroplating pool cooling, cooling of the electronics industry, the chemical industry of cooling, cooling of the pharmaceutical industry, food industry cooling, the cooling thermostat preservation industry, air-conditioning cooling species
    Industrial water chiller for attention
    1, unit run-time power supply voltage must be stable, considering all factors, blood pressure, the work crew to maintain the rated voltage of less than + -10%, voltage too high or too low are the adverse effects of the crew.
    2, power frequency should be maintained at rated + -2%.
    3, for the protection of human security, if the body leakage avoid the risk of electric shock, Shell should have a good crew, reliable ground fault protection device has been accidents, according to strict regulations require construction electrician.
    4, transportation or move out room, do not impact with the ground, causing too much impact.
    5, the room should have sufficient space for the installation and maintenance unit, taking into account the adequate space extubation.
    6, the installation of the selected sites:
    ①, avoid direct sunlight installations or other heat source will be directly radiation areas.
    ②, from power nearly facilitate wiring.
    ③, solid ground strength, and the noise does not easily cause resonance of places.
    ④, placed in the house, choose a well-ventilated, humidity small, less suitable places.

    7, to facilitate the discharge cooling water and chilled water, basic units must be installed around the gutter.
    8, chilled water and cooling water undesirable not only led to the scaling of heat transfer, heat transfer efficiency from lower and the weakening performance unit will heat pipe corrosion caused major accidents, customers should be in strict accordance with the GB50050-1995 "Design of industrial circulating cooling water treatment norms "at the request of water treatment.
    9, vertical flow switch should be installed in the outlet pipe into the pipes or the level of the paragraph.
    10, flow switch to the direction of flow at least six times the pipeline diameter of straight pipe section; flow switch to the direction of flow at least four times the diameter of straight pipe pipeline paragraph; should not be installed in the near Bend, in the vicinity of the valve orifice and .
    11, in order to prevent flow switch trembled, the water system should be all of the gas emissions out.
    12, Australian customs regulation flowmeter, it is lower than the minimum flow of water in a state separate from the flow. When the water flow to meet the requirements, flow switch should remain closed state.





    Specifications:low noise ,high reliability,low vibration,high efficiency
    Export Markets:millde east; south america;africa
    various compressors  is used for air-conditioner as a replacement parts ,and they are high quality and excellent matching.
    Member ID:
    Password:
     
    HiSupplier Online
    Welcome to our website !
    HiSupplier Online