You are here:  homeproductsR22 & R407C Series Piston CompressorsPiston A/C Compressor
Products List
  • Air-Conditioning Compressor Series
  • Stable Speed Series Compressors
  • H Type Compressors
  • D Series Compressors
  • Inverter Series Compressors
  • R410A Series Compressors
  • R134a Series Compressors
  • Air-Conditioning Scroll Compressors
  • Semi-hermetic Reciprocating Compressors
  • 06D Series Piston Compressors
  • 06E Series Piston Compressors
  • 06CC Series Piston Compressors
  • R134a Series Compressors
  • R404A/R507A Series Compressors
  • R407C Series Compressors
  • R22 Series Compressors
  • Horizontal Compressor Series
  • R22 Series Horizontal Rotary Compressors
  • R407C Series Horizontal Compressors
  • Vertical Compressor Series
  • R22 Series Vertical Compressors
  • R407C Series Vertical Compressors
  • R410A Series Vertical Compressors
  • Piston A/C Compressor Series
  • R12 Series Piston Compressors
  • R22 Series Piston Compressors
  • R22 & R407C Series Piston Compressors
  • Low Temperature Chiller Unit Series
  • LHJL Series Low Temperature Unit
  • LXJL Series Low Temperature Unit
  • Industrial Water Chiller Unit Series
  • Car Air Conditioning Compressors
  • Fixed Displacement Compressors
  • DY5H09
  • DY5H11
  • DY5H14
  • DY5H16
  • DYHT6
  • DY7B10
  • DY7H13
  • DY7H15
  • DY10P08
  • DY10PA15C
  • DY10PA17C
  • DY10S17C
  • DY10S20C
  • Variable Displacement Compressors
  • DYV5
  • DYCVC
  • DY6V12
  • DY7V16
  • DY7SBU16C
  • Refrigerating Units
  • Environment-Friendly Chillers
  • Industrial Chillers
  • Screw Type Chillers
  • Laser Chillers
  • Heat and Cold Chillers
  • Low Temperature Chillers
  • PCB Chillers
  • Cooling Towers
  • Air-Coolers
  • Heating Pump Series
  • Household Series
  • Villa Servies
  • Individuality Series
  • Import Series
  • Floor-heating Equipment
  • Swimming Pool Equipment
  • Heating and Ventilation series
  • Energy Saving Air Curtain Series
  • Classical Air Curtain Series
  • Exalted Air Curtain Series
  • Faddish Air Curtain Series
  • Cultured Air Curtain Series
  • Deluxe Air Curtain Series
  • Industrial Exhausting Fan Series
  • Air-conditioning Parts
  • Refrigerant Series
  • Capacitor Series
  • Metallic Polypropylene Film Capacitors
  • Aluminium Electrolytic Capacitors
  • Power Capacitors
  • Brass Fitting Series
  • Copper Fitting Series
  • Insulated Pipe Fitting Series
  • 4-way Reversing Valves
  • Solenoid Valves
  • Pressure Switches
  • Expansion Valves
  • Sighe Glasses
  • Filter Drieres
  • air conditioner plastic Fan Blades and metal fanblade Series
  • Axial Fans with External Rotor Motor
  • Fan Motors
  • YWF Series Axial Motors
  • YZF Series Axial Motors
  • YJF Series Axial Motors
  • Fan Blades
  • Cross Flow Fan Blades
  • Axial Flow Fan Blades
  • Centrifugal Flow Fan Blades
  • Home Electrical Parts series
  • Rubber Washing Machine Parts Series
  • Gear Box Series
  • Washing Machine Connection Pipes
  • Online Service
    Forrest:  
    Piston A/C Compressor
    View more specifications Piston A/C Compressor for you
    Model No: R22 Series & R407C Series
    Place of Origin: Zhejiang
    Function: air-conditioner
    Certificate: TUV CE ROHS
    Export Area: millde east; south america


    Add to Basket
     Description
    Payment & Shipping Terms
    Payment Term: T/T,L/C;D/P  
    MOQ: 50 pcs  
    Means of Transport: by sea ;by air ;by train  
    Supply Capacity
    Packing: with requirement
    Delivery Date: 30 days
    RC series Performance Table
    R22 R407C Power Specification Run Capacitor (μF/450V)
    Model Nominal Capacity Input Power (kw) Working Current; A COP (W/W) Nominal Capacity Input Power (kw) Working Current A COP (W/W)
    W BTU/H W BTU/H
    LW-T18 3881 13200 1.45 7.00 2.68 3726 12670 1.39 6.80 2.68 220V~50Hz 50
    2.73 2.47 380V~50Hz
    LW-T28 7378 25090 2.55 12.1 2.89 6137 20865 2.35 4.40 2.61 220V~50Hz 60
    4.56 4.39 380V~50Hz
    LW-T36 9272 31520 3.37 15.8 2.75 7994 27180 3.12 15.20 2.56 220V~50Hz 100
    5.57 5.71 380V~50Hz
    LWT50 12324 41900 4.32 8.46 2.85 11266 38304 4.11 7.34 2.74 380V~50Hz  
    LW-T64 15820 53788 5.66 9.54 2.79 14587 49600 5.25 9.35 2.78 380V~50Hz  
    LW-T80 19534 66415 7.13 22.58 2.74 18525 62990 6.83 11.83 2.71 380V~50Hz  
    LW-T100 23403 79570 7.98 15.59 2.93 22111 75180 7.85 13.58 2.82 380V~50Hz  
    LW-T125 30429 103460 10.66 17.37 2.85 29212 99320 10.15 16.00 2.88 380V~50Hz  
    LW-T144 34340 116750 11.95 19.75 2.87 32934 111980 11.57 18.46 2.85 380V~50Hz  
    LW-T160 38273 130130 13.39 22.16 2.86 37386 127110 13.28 21.40 2.82 380V~50Hz  
    Test Conditions
    R22 (1)Evaporating Temp.=7.2℃ (45o F)
    (2)Condensing Temp.=54.4℃ (130o F)
    (3)Sub cooling Temp.=8.3K
    (4)Suction Temp.=11.1K,
    R407C (1)Evaporating Temp.=7.2℃ (45o F)
    (2)Condensing Temp.=54.4℃ (130o F)
    (3)Sub cooling Temp.=8.3K
    (4)Suction Temp.=11.1K,
    Completely closed refrigeration compressor piston attention
    1, the compressor removal process should be maintained-home, light caving, tilt angle not greater than 45 °.
    2, the compressor and the ground level should remain vertical, the largest installation tilt angle is less than 5 °.
    3, compressor factory before adequate refrigeration oil injection, the use of not arbitrarily add and also not arbitrarily increase other brands of frozen oil, or they may cause operational failure.
    4, compressor refrigeration system installed in the former and not to suction and exhaust outlets, rubber Cypriots out in the process. Access System should be within 10 minutes assembly, welding, so as not to enter the water in the air compressor and refrigeration system to produce the harm.
    4, oil / refrigerant than the recommended weight for 0.4 and above (oil proportion 0.92).
    5, refrigerant from the condenser refrigeration system into the tail end, and not directly into the compressor.
    6, when the compressor in the vacuum will not be high voltage test or launch test.
    7, should not try to start without the compressor package actuating devices.
    8, in order to avoid the problem started in the pre-commencement for the first time in 10 ° C above the compressor environment.
    9, in the compressor are not allowed to use antifreeze, antifreeze will be damaged because such a concentrated material used. Antifreeze in particular that the content of ethanol and methanol synthesis of motor insulation destructive role.
    10, installed in the cooling system of compressors, refrigeration agent in charge after 15 minutes, the compressor must be running 20 seconds more. Have to start again after the shutdown intervals three minutes more.
     
    Specifications:low noise ,high reliability,low vibration,high efficiency
    Export Markets:millde east; south america;africa
    various compressors  is used for air-conditioner as a replacement parts ,and they are high quality and excellent matching.
    Member ID:
    Password:
     
    HiSupplier Online
    Welcome to our website !
    HiSupplier Online